The scientific and rigorous work style formed over the years, from the raw materials entering the factory, to the entire production process, to the product leaving the factory, has complete and strict monitoring and inspection procedures to ensure high quality and high efficiency Low intensity twin B light, Solar low intensity light type A, Medium intensity obstacle light B. We introduce advanced technology at home and abroad, adhere to sustainable development, and ensure the dominant position of our products. Based on the spirit of reputation first and customer first, the company wholeheartedly serves all customers and sincerely hopes to establish extensive cooperation with customers at home and abroad.
Airport Isolation Transformer
Airport Isolation Transformer,
airport use isolation transformer,
China Airport Isolation Transformer,
Airport Isolation Transformer price.

Compliance
Compliance with Standards
CAAC: MH/T 6008
ICAO: DOC 9157,Part 5,Para.3.2
IEC: TS 61823
FAA: AC 150/5345-47
Application/Use
Airport isolation transformer is widely used in Airport runway, taxiway or apron 2.8-6.6A constant current input circuit
Features
All series of specifications,structure, electrical and other properties of airport isolation transformers meet the requirements of FAA, ICAO and IEC;
Use international standard plugs and sockets to meet the connecting requirements of FAA standard lamps;
Made of special rubber and plastic materials, super anti-aging performance, corrosion resistance, kerosene resistance, urea resistance, to ensure long-term stability of high insulation and reliability;
Use integral injection process to ensure the joint parts of the connector are firmly connected with the body;
The internal frame is designed to ensure that the primary coil and the secondary coil are fully isolated;
The use of high quality silicon steel sheet greatly guarantees the electrical performance of the product.
15KV high voltage resistance, hot insulation resistance greater than 7500 MEG, leakage current less than 2 A;
The earthing resistance is less than 4 Ω. The grounding is reliable and
high degree of safety;
The working temperature is -55 ℃ to +65 ℃, stable work performance;
With earthing or non grounding type can be selected by users;
Special socket / plug protector to ensure plug and socket are free from moisture and dust.
Structure

1.Ground NutM5(Earthing Type)
2.Isolation transformer body
3. Primary plug / socket cable
4. Style 2 Primary plug
5. Style 9 Primary socket
6. Secondary socket cable
7. Style 8 Secondary socket
Ordering
Ordering Information

Installation

Detailed installation information refer to the product instructions
Wiring diagram

CCR:Constant Current Regulator
L:Light Fixtures
ST:Series connection isolation transforme
Accessories
Please refer to the below form for plugs and packages matching the isolation transformer.
|
Type |
Order No. |
Remarks |
|
Secondary Calbe Plug (A4) |
971733 |
Style 4 Combined Kit, |
|
Primary cable plug& plug kit (A3 A10) |
971730 |
Style 3 Sytle 10 Combined Kit, Recommend to use * |
|
Secondary Calbe Plug (A6) |
70603 |
Style 6 |
|
Secondary Calbe Plug (A2) |
70206 |
Style 2 |
|
Secondary Calbe Plug (A9) |
70906 |
Style 9 |
|
ITF thermoplastics accessories kit
|
970001
|
Contain connector style 2 style 9 |
Technical Data
|
FAA Specified number |
Type (W) |
Main Circuit current |
Power factor |
Power |
Pressure resist- |
Full load current of secondary circuit (A) |
Open circuit voltage of secondary circuit (V) |
|
L-830/8 31- 16 |
10/15 |
6.6 A |
≥0. 9 5 |
≥70 |
5000 |
6.53 - 6.67 |
<8 |
|
L-830/8 31- 17 |
20/15 |
6.6 A |
≥0. 9 5 |
≥70 |
5000 |
6.53 - 6.67 |
<8 |
|
L-830/8 31- 1 |
30/15 |
6.6 A |
≥0. 9 5 |
≥70 |
5000 |
6.53 - 6.67 |
<25 |
|
N/A |
50 |
6.6 A |
≥0. 9 5 |
≥70 |
5000 |
6.53 - 6.67 |
<25 |
|
L-830/8 31- 3 |
65 |
6.6 A |
≥0. 9 5 |
≥70 |
5000 |
6.53 - 6.67 |
<30 |
|
L-830/8 31- 4 |
100 |
6.6 A |
≥0. 9 5 |
≥70 |
5000 |
6.53 - 6.67 |
<70 |
|
L-830/8 31- 18 |
150 |
6.6 A |
≥0. 9 5 |
≥70 |
5000 |
6.53 - 6.67 |
<70 |
|
L-830/8 31- 6 |
200 |
6.6 A |
≥0. 9 5 |
≥70 |
5000 |
6.53 - 6.67 |
<100 |
|
L-830/8 31- 10 |
300 |
6.6 A |
≥0. 9 5 |
≥70 |
5000 |
6.53 - 6.67 |
<135 |
Packing Data
![]() |
![]() |
|
Type |
B(mm) |
L(mm) |
H(mm) |
|
15W |
110 |
101.2 |
76 |
|
25W |
110 |
101.2 |
85 |
|
45W |
126.5 |
121 |
90. 7 |
|
50W |
126.5 |
121 |
90. 7 |
|
65W |
126.5 |
121 |
102.7 |
|
100W |
134 |
130 |
100.7 |
|
150W |
141.5 |
139 |
110.7 |
|
200W |
157.5 |
158.2 |
111 |
|
300W |
157.5 |
158.2 |
131 |
We take full consideration of the actual needs of our customers, and make well-structured and high-quality Dry-Type Natural Air Cooling Electric Power Transformer Without Shell. In today's world, science and technology are advancing by leaps and bounds. Our company attaches great importance to the important role of scientific and technological progress in economic and social development. Paired with flexible manufacturing systems, we deliver a wide range of the best quality products within a competitive lead time and the most professional services to our customers in an array of applications and industries.