Knowledge

Aviation Obstruction Light Distribution Requirements Power Modulation Control Mode

Jun 30, 2022 Leave a message

Aviation Obstruction Light Distribution Requirements Power Modulation Control Mode


Requirements for the installation and distribution of aviation obstruction lights, like cheap low intensity twin B, cheap low intensity type B, low intensity twin B factory, China medium intensity type A.


1. The obstacle should be marked with the highest point and the most edge (ie apparent height and apparent width) of the obstacle in terms of the setting of its obstacle lights. One or more low, medium or high intensity obstacle lights must be as close as practicable. The top of the object is set, and the obstruction lights at the top must be arranged to at least show the highest point or the highest edge of the object relative to the obstacle restriction surface, but in actual use, due to the consideration of lightning protection, it is generally indented according to different heights. 1 to 3 meters. For chimneys or other similar structures, the top lights should be set at a low enough position below the top to minimize pollution by smoke, etc. Generally, the beacon lights are 3 to 5 meters lower.


2. If the top of the object is more than 45 meters above the ground around it, obstruction lights must be added on the middle layer of the object, and the distance of each layer of obstruction lights must be no greater than 45 meters and as equal as possible (super-high buildings of more than 100 meters in the city) In particular, the installation of obstacle lights on the middle layer should be considered. When installing middle layer obstacle lights in buildings located near cities and residential areas, consideration should be given to avoid glare for residents. Generally, only scattered light can be seen from the ground.


3. Obstruction lights set up in buildings with a large shape should be able to see the outline of the building from all aspects. The horizontal direction can also refer to setting up obstruction lights at a distance of about 45 meters.


4. For super-high objects, facilities or iron towers, towers, etc. with aviation obstruction lights at 105 meters, medium-intensity A-type obstruction lights should be set at the top of them, and flash white, and red medium-intensity lights should be set on the lower part of the layer. Type B obstruction lights, when the top of an obstacle marked by a type A medium-intensity obstruction light is more than 105 meters above the top elevation of the surrounding ground or nearby buildings (when the obstacle is surrounded by multiple buildings), it must be Additional obstruction lights in the middle must be installed at an equal height of not more than 105 meters between the top obstruction lights and the ground or the top level of nearby buildings, depending on the situation.


Aviation obstruction light power supply combined flashing main light cable outlet is four-core, aviation light brown wire and black wire are power wire, blue wire is power output wire, yellow-green wire is ground wire, auxiliary light is three-core wire, brown wire And the blue wire is the power wire, and the yellow-green wire is the ground wire.


a. Synchronous connection of the main and auxiliary lights for power modulation: connect all the blue lines of the auxiliary lights that need to be flashed together with the blue line of the main light in parallel, and the brown line and the brown line of the main light should also be connected in parallel. After the wire is grounded, we just need to power up the main light and it will run normally.


b. Control mode connection of the power modulation controller: During installation, connect all the auxiliary lamp power lines and the output lines of the power line of the controller together. After the yellow and green lines are grounded, the controller can work normally when it is powered on.


Send Inquiry